An unsatisfactory EICR means safety work or further investigation is needed; TMB Electrics can identify the remedial electrical work and provide written pricing.

## Why is an EICR unsatisfactory?

An EICR is unsatisfactory when it records a C1, C2 or FI finding. These codes identify danger, potential danger or an item needing further investigation.
- **C1 danger present:** A C1 finding means danger is present and urgent action is needed. The report identifies the part of the installation that needs attention.
- **C2 potentially dangerous:** A C2 finding means a defect could become dangerous. The remedial work needs addressing before the installation can receive a satisfactory result.
- **FI further investigation:** FI means further investigation is needed before the condition of part of the installation can be established. The report remains unsatisfactory while that finding is open.
- **A C3 does not make the report unsatisfactory:** A C3 records an improvement recommendation. It does not make an EICR unsatisfactory, although the report explains the improvement recommended.

## What can I check safely after an unsatisfactory EICR?

You can read the report, note the affected rooms and look for visible signs of damage. Leave consumer units, sockets, switches, appliances and fixed wiring closed.
- **Read the observation codes:** Check whether each finding is marked C1, C2, C3 or FI. Note the circuit and location written beside each observation.
- **Look for visible heat damage:** Look without touching for scorching, smoke, cracking, unusual warmth or a burning smell around accessible sockets, switches and light fittings.
- **Keep damaged items out of use:** Leave plug in appliances with damaged plugs, heat marks or a burning smell disconnected. Do not open the appliance or attempt a repair.

## When should I book remedial electrical work?

Book remedial electrical work when the report records C1, C2 or FI findings. Immediate signs of overheating or damage need the affected circuit left unused.
- **The report records C1 or C2:** C1 and C2 findings need remedial electrical work. The report helps identify the circuit, accessory or protective equipment that needs attention.
- **The report records FI:** An FI finding needs further investigation before the underlying condition is known. Testing identifies what requires repair or replacement.
- **There is smoke, scorching or heat:** Smoke, scorching, unusual warmth or a burning smell at an electrical fitting needs urgent attention. Stop using the affected circuit.

## What happens during a failed EICR remedial visit?

The visit starts with the report findings and the affected installation. Testing then establishes the work needed before any remedial electrical work is priced.
- **The report findings are checked:** The coded observations are checked against the consumer unit, circuits and accessories named in the EICR.
- **The affected work is tested:** Testing examines the reported fault or investigates the FI finding. This identifies whether the issue is in a circuit, connection, fitting or protective device.
- **The remedial work is priced:** The work needed is set out with written pricing once the cause and required parts are known.
- **The completed work is recorded:** Completed electrical work is tested and documented where the work requires it. The records show the work carried out on the installation.

## What does failed EICR remedial work cost?

The price covers the testing needed to check the findings and the remedial electrical work identified from that inspection. It changes with the number of findings, the circuits involved, access to the installation, replacement parts and whether further investigation is needed.
- Consumer unit (CCU) replacement: from £375
- C1, C2 and FI findings may need different work, so each remedial price follows the report and testing.
- Replacement parts, circuit repairs and consumer unit work change the price when they are required.
- A C3 recommendation can be priced separately when you want the improvement carried out.

## Unsatisfactory EICR questions

### What makes an EICR unsatisfactory?

An EICR is unsatisfactory when it includes a C1, C2 or FI finding. C1 means danger is present, C2 means potentially dangerous, and FI means further investigation is needed. A C3 recommendation does not make the report unsatisfactory.

### Can I still use the electricity after a failed EICR?

The report identifies which finding needs attention and where it is located. Do not use a circuit, socket, switch or fitting with smoke, scorching, a burning smell or unusual warmth. Leave damaged plug in items disconnected.

### Do I need a new consumer unit after an unsatisfactory EICR?

Not every unsatisfactory EICR needs a consumer unit replacement. The report and testing identify whether the finding concerns the consumer unit, a circuit, a connection or another electrical fitting. Consumer unit work is priced separately when it is needed.

### What happens after C1, C2 or FI work is completed?

The completed electrical work is tested and documented where required. The records show the remedial work carried out and support the next step for the installation.

## Related problems
- [Burning smell from the fuse box](https://www.tmbelectrics.co.uk/problems/burning-smell-from-fuse-box): A burning smell at the consumer unit can mean an overheating connection or protective device.
- [Fuse box in the bathroom: is it legal?](https://www.tmbelectrics.co.uk/problems/fuse-box-in-bathroom): A fuse box in a bathroom breaks the wiring regulations and needs moving to a dry place outside the room.
- [Fuse box sparking](https://www.tmbelectrics.co.uk/problems/fuse-box-sparking): Sparks from a consumer unit need the affected electrical installation checked urgently.
- [Old fuse box: do I need to upgrade?](https://www.tmbelectrics.co.uk/problems/old-fuse-box): An old fuse box needs testing before replacement, because the wiring behind it matters too.
- [Signs your fuse box needs upgrading](https://www.tmbelectrics.co.uk/problems/fuse-box-needs-upgrading): Signs an older fuse box needs testing or replacement before new electrical work.
- [Still got rewirable fuses at home?](https://www.tmbelectrics.co.uk/problems/rewirable-fuses): Rewirable fuses need testing before a consumer unit replacement is planned.

## Sources
- [BS 7671: IET Wiring Regulations](https://electrical.theiet.org/bs-7671/)
- [HM Government: Approved Document P](https://www.gov.uk/government/publications/electrical-safety-approved-document-p)
- [GOV.UK: Electrical safety standards in rented homes](https://www.gov.uk/government/publications/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance/electrical-safety-standards-in-the-private-and-social-rented-sectors-guidance)

Updated 2026-11-19.

[Consumer unit replacement](https://www.tmbelectrics.co.uk/services/fuse-board-replacement)

## Book or ask a question
- [Book Now](https://www.tmbelectrics.co.uk/#chat)