Induction hob tripping the electrics

TMB Electrics finds why an induction hob trips the electrics in Banstead by testing the hob circuit and the hob separately, so you learn whether the fault sits in the wiring, the connection or the hob.

Calls answered 24/7

  • 14 years trading
  • Local to Banstead
  • Clear, upfront quotes

Why does an induction hob trip the electrics?

Three places account for most trips: the hob, the connection between hob and circuit, and the circuit itself. How the trip behaves tells us where to look first.

  • A fault inside the hobA fault inside the hob can leak current to earth. That usually trips the RCD, the safety switch that cuts power when current escapes, the moment the hob switches on.
  • A loose or damaged connectionA loose, damaged or wrongly made connection at the hob terminal block or connection unit can arc or leak current. A flex pinched between the hob and the worktop cut out can do the same.
  • Hob and oven together overload the circuitA hob and a built in oven running together can draw more current than the circuit and its breaker carry. The breaker then trips only when both are on.
  • A circuit shared with other loadsWhen the hob shares a circuit with sockets or other appliances, their load adds to the hob's. The trips can then look random, because they depend on what else is running.
  • A failing RCD or breakerThe protective device itself can wear out. If the trip stays after we disconnect the hob, the device or the circuit needs attention, not the hob.

What can I check safely at home?

Each check uses only the hob controls, the switch on the consumer unit and your eyes. Nothing opens the hob or reaches its wiring.

  • Switch off and reset onceTurn the hob off at its isolator or wall switch, then reset the tripped breaker or RCD once. If it holds, the trip may belong to one particular use of the hob.
  • Note exactly when it tripsWrite down whether it trips as the hob goes on, on one zone only, or only with the oven running. That pattern tells us where to start testing.
  • Look for anything trappedCheck that no pan, cable or loose item is trapped against the hob. A burning smell or a hot switch or flex means the hob stays off.
  • Keep it off after a second tripIf it trips again, leave the hob off and cook another way. Do not lift the hob out or touch its connection.

When should I book an electrician?

Book when the trip repeats, when the cause is not obvious, or when anything looks or smells wrong around the hob.

  • It trips more than onceA second trip means the fault is still there. Resetting again only repeats the trip and leaves the cause untouched.
  • It trips the moment the hob goes onAn instant trip usually points to current leaking inside the hob or at its connection. That needs testing before the hob is used again.
  • The circuit also feeds other thingsA hob sharing a circuit with sockets or appliances can overload it. The fix is often a circuit of its own or an RCBO, a breaker with RCD protection built in.
  • A burning smell or a hot switchLeave the hob off and book the same day. Heat at the switch or flex is a fire risk.

What happens on the visit?

The visit starts with what you noticed, then works through the circuit and the hob in order.

  • Symptoms and the trip patternWe ask when it trips and which zones or oven settings were in use. Then we look at the consumer unit and the circuit that serves the hob.
  • Test the circuit and the hob flexWe isolate the circuit and test insulation resistance, how well the cable keeps current inside, and earth continuity, an unbroken path to earth. Both tests run on the circuit and on the hob flex.
  • Disconnect the hob to split the causeWe disconnect the hob and see whether the trip stays. A trip that stays points to the circuit or its protective device. A trip that goes points to the hob or its connection.
  • Remake or replace what has failedDamaged connections, the connection unit or the flex are remade or replaced where they are at fault. A shared or overloaded circuit may get a circuit of its own or an RCBO, priced first. If the circuit tests clean, we say so and point you to the hob maker.

What does the fault finding price cover?

Fault finding is charged by the hour for the diagnostic visit, and that time goes on testing the hob circuit, its connection and the protective device until the cause is found. The price changes once the cause is known, because a repair, a new circuit or new parts are priced on top.

From £80 an hour

Included when agreed

  • Testing the affected circuit and the fuse board
  • Tracing the fault to the socket, fitting, cable or appliance
  • Repairs that can be done on the spot with parts carried
  • A clear explanation of what was wrong

Not included automatically

  • New circuits or upgrades the fault reveals, which are quoted separately
  • Repairs to the appliance itself

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Pay by bank
  • Bank transfer
  • The hourly charge buys testing of the circuit, the connection and the protective device.
  • Remade connections, a new flex or connection unit and any parts are priced once the fault is found.
  • A circuit of its own for the hob, or a suitable RCBO, is quoted before any work starts.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose TMB Electrics

Photo of Trevor BushTrevor BushElectrician
Reviews
39
Rating
5.0
Trading since
2012
“I keep things straightforward: you deal with me from the first quote to the final check, with clear advice and no surprises along the way.”

Trevor Bush, TMB Electrics

Book Now

Induction hob tripping questions

Still have a question?

Why does my induction hob trip the RCD?

The hob may have a fault, its connection may be loose or damaged, or the circuit may be overloaded or shared. We test the circuit and the hob separately to find which.

Will the hob need its own circuit?

A hob sharing a circuit with other loads is a common reason for trips. When that is the cause, we quote a circuit of its own or a suitable RCBO before any work starts.

Can I bypass the RCD to keep cooking?

No. A trip is the protection working and a sign of a fault, so it is never bypassed. Leave the hob off and we find the cause.

What if the circuit tests fine?

We tell you so and point you to the hob maker or an appliance engineer. The testing still shows that the wiring and its protection are not the cause.