Shaver socket not working
A shaver socket that has gone dead usually has lost its supply from the circuit or has a failed unit, and TMB Electrics in Banstead tests where the power stops and repairs it.
Calls answered 24/7
- 14 years trading
- Local to Banstead
- Clear, upfront quotes
Why is my shaver socket not working?
A bathroom shaver socket is a sealed unit on a protected circuit, so it can fail or lose power while the rest of the house works normally.
- The circuit or RCD has trippedAn RCD is the safety switch in the consumer unit that cuts power when current leaks. Every circuit in or passing through a bathroom has one, so a trip elsewhere on it can take the shaver point with it.
- It shares the lighting circuitMany shaver units take their power from the lighting circuit. A dead bathroom light and a dead shaver point often share one cause.
- The shaver unit has failedA shaver socket contains an isolating transformer, which separates the shaver from the mains. That sealed part can wear out on its own, with nothing else in the house wrong.
- A connection has come looseA loose or heat damaged connection at the unit, or at the junction box that feeds it, stops power reaching the socket. Heat marks around the unit point to this.
- A mirror light has its own fuse or switchA mirror light or bathroom cabinet with a built in shaver socket can have a small fuse or switch of its own. If that has operated, only the shaver point goes dead.
What can I check safely at home?
Everything below can be done with dry hands at the consumer unit and the bathroom wall, without opening the unit or touching wiring.
- Reset a tripped switch onceLook at the consumer unit for a tripped RCD or breaker and switch it back on one time. If it drops out again, leave it off.
- Try the bathroom lightIf the light is dead too, the fault is on the circuit that feeds both rather than in the shaver unit itself.
- Test the shaver elsewhereIf the supply trips the moment the shaver goes in, charge the shaver in another room with the adaptor that came with it and leave the bathroom unit alone.
- Look for a switch or fuse on the frontSome units and mirror lights have a small switch or fuse marked on them. Check the switch is on before you do anything else.
- Leave the unit in the wallDo not swap in an ordinary socket, run an extension lead from another room or open the unit. A bathroom is a wet room, and wet skin raises the risk of shock.
When should I book an electrician?
Book when one reset has not brought the socket back or when the unit shows damage. Use Book Now to arrange the visit.
- The socket stays dead after one resetA shaver point with no power after the circuit has been reset needs testing to find where the supply stops.
- The circuit trips againA breaker or RCD that keeps switching off points to a fault that resetting will not clear. Leave that circuit off.
- The unit is cracked, discoloured or has been wetWater, cracks or brown marks on a shaver unit mean it should stay out of use until it has been tested.
- The light on the same circuit has also failedTwo dead fittings on one circuit show the fault sits upstream of the shaver unit, at a joint or the circuit protection.
What happens on the visit?
The visit starts at the shaver unit and consumer unit, then follows the supply until the point where it stops is found.
- Isolate and test the circuitWe switch off the circuit and test at the consumer unit, the junction box and the shaver unit to find where power stops.
- Check the RCD protectionEvery circuit in or passing through a bathroom needs RCD protection, so we confirm the circuit has it and works.
- Repair or replace the failing partA loose or heat damaged connection is remade. A failed unit is replaced with a proper shaver supply unit, never an ordinary socket.
- Test and leave the paperworkThe circuit is tested before power goes back on. Bathroom electrical work falls under Part P of the Building Regulations, so we leave the paperwork the job needs.
How is shaver socket fault finding priced?
The price covers the time spent isolating the circuit and testing until we find why the shaver point has no power. It changes when testing finds a failed unit, a damaged cable or a loose joint that needs parts, because the repair is priced once the cause is known.
From £80 an hour
Included when agreed
- Testing the affected circuit and the fuse board
- Tracing the fault to the socket, fitting, cable or appliance
- Repairs that can be done on the spot with parts carried
- A clear explanation of what was wrong
Not included automatically
- New circuits or upgrades the fault reveals, which are quoted separately
- Repairs to the appliance itself
Ways to pay


- Pay by bank
- Bank transfer
- Fault finding is charged by the hour for the diagnostic visit.
- A replacement shaver unit and any other parts are quoted separately once the fault is found.
- Bathroom work comes with the testing and paperwork it requires.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose TMB Electrics
- Reviews
- 39
- Rating
- 5.0
- Trading since
- 2012
“I keep things straightforward: you deal with me from the first quote to the final check, with clear advice and no surprises along the way.”
Trevor Bush, TMB Electrics
Book NowCan I put a normal socket in my bathroom instead?
No. Bathrooms and shower rooms can only have shaver supply units, unless an ordinary socket sits at least 2.5 metres from the edge of the bath or shower tray. A shaver unit is built differently for that reason.
Why is my shaver socket dead but the bathroom light works?
The two may be on different circuits, or the shaver unit may have failed or lost a connection. Testing shows where the supply stops.
Can I charge my shaver from a socket in another room?
Yes, using the adaptor that came with the shaver and following the maker's instructions. Keep it unplugged when you are not charging it.
Does replacing a shaver socket need a certificate?
Bathroom electrical work falls under Part P of the Building Regulations, so it should be done by a registered electrician. We test the circuit and leave the paperwork the work needs.
Related problems
- Burning plastic smell from electricsA burning plastic smell needs the affected electrical circuit checked before it is used again.
- Circuit breaker keeps trippingA repeated trip usually means a circuit, fitting or connected item needs testing.
- Circuit breaker will not resetA circuit breaker that stays off needs the affected circuit checked for a fault.
- Consumer unit is hotA hot consumer unit can point to an overloaded circuit or failing connection that needs testing.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in usually needs the fixed circuit traced and tested.
- Cooker tripping the electricsA cooker trip can come from its circuit, connection or the appliance itself.
Sources
- Electrical Safety First: bathroom safety
- Electrical Safety First: shavers
- GOV.UK: Approved Document P, electrical safety in dwellings
Updated 20 November 2026