EICR and electrical testing in Worcester Park
EICR testing in Worcester Park begins with the fixed-wiring boundary, previous records and confirmed access to every agreed area.
Calls answered 24/7
- 14 years trading
- Local to Banstead
- Clear, upfront quotes
Pricing for electrical condition reports
Pricing for an electrical installation condition report reflects the size of the property and the complexity of its electrical system. We provide straightforward quotations before starting any work.
From £150
EICR: from £150
Commercial EICR: from £150
Included in the inspection
- Consumer unit, circuit protection and RCDs
- Fixed wiring and every circuit
- Sockets, switches, lighting and fixed appliances
- Earthing and bonding
- A written report with any findings coded C1, C2, C3 or FI
Ways to pay


- Pay by bank
- Bank transfer
- The price covers the complete visual examination, instrument testing of circuits, and the completed condition report document.
- Pricing varies based on the total number of circuits, additional consumer units, and whether the premises are domestic or commercial.
- Remedial repair work to address identified defects is quoted separately after the condition report is completed.
EICR and electrical testing across Worcester Park
We serve Worcester Park from our base in Banstead.
What happens on the day
An electrical inspection requires methodical testing of the complete fixed installation, starting at the main intake and working through each circuit. Testing is conducted with parts of the power disconnected in stages to record accurate electrical readings.
- Visual inspection of the consumer unit and wiring accessoriesWe examine the incoming electrical supply, earthing conductors, bonding conductors, and the main consumer unit. We also inspect a sample of socket outlets, light fittings, and switches across every room for signs of physical damage, overheating, or loose connections.
- Dead testing of isolated electrical circuitsEach circuit is switched off and isolated in sequence. We use calibrated test instruments to measure continuity of protective conductors and check insulation resistance between conductors, identifying hidden cable degradation inside walls or under floorboards.
- Live electrical testing and residual current device checksOnce dead testing is complete, circuits are re-energised to measure earth fault loop impedance and prospective fault currents. We test residual current devices to confirm they trip within required millisecond safety limits when an electrical fault occurs.
- Immediate review of test results and documentationBefore finishing the on-site visit, we explain all findings directly to the property owner or manager. We note any observed issues, outline the reasons behind each code, and follow up with the formal written report detailing every circuit measurement.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Follow your job from booking to receipt
See when we're on our way, get your job report the moment we finish, and pay in seconds.
Track us on our way
See us on the map with a live arrival time.
Your job report, same day
See exactly what was done as soon as we finish.
Invoice and receipt in one place
Pay online in seconds, and your receipt is always there when you need it.
Why choose TMB Electrics
- Reviews
- 38
- Rating
- 5.0
- Trading since
- 2012
“I keep things straightforward: you deal with me from the first quote to the final check, with clear advice and no surprises along the way.”
Trevor Bush, TMB Electrics
Book NowPhotos of our work
How often does a rented home in Worcester Park need an EICR?
Rented residential properties in England must have an electrical inspection at least every five years, or sooner if an earlier retest date was recommended on the previous report. Landlords must give a copy of the satisfactory report to current tenants within 28 days and to incoming tenants before their tenancy begins.
Will the electricity be turned off during the electrical test?
Yes, the electrical supply must be isolated in stages to carry out dead testing safely. Circuits are turned off one by one to test cable insulation and earth continuity, followed by live functional testing. We plan this process carefully to minimise disruption to refrigeration and computing equipment.
What happens if an electrical condition report is unsatisfactory?
If an inspection reveals C1, C2, or FI outcome codes, the report is deemed unsatisfactory. We explain the exact defects found and provide a separate written quotation for the required remedial work. Once repairs are completed, appropriate documentation is issued confirming the installation is safe.
Does a C3 observation code mean my property has failed the check?
No. A C3 code is an advisory recommendation indicating that an aspect of the installation could be improved to meet modern standards, but it poses no danger. A report with only C3 notes remains satisfactory, and the recommended improvements can be carried out whenever you choose.
How long does an EICR visit usually take?
A standard domestic inspection takes between two and four hours, depending on the property layout, the number of consumer units, and how many circuits need testing. Larger properties or commercial buildings with multiple distribution boards require additional time to test thoroughly.
